Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Biomedicines ; 11(12)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38137447

RESUMO

This single center study includes a comparative analysis of the diagnostic performance of full-field digital mammography (FFDM), contrast-enhanced mammography (CEM) and automatic breast ultrasound (ABUS) in the group of patients with breast American College of Radiology (ACR) categories C and D as well as A and B with FFDM. The study involved 297 patients who underwent ABUS and FFDM. Breast types C and D were determined in 40% of patients with FFDM and low- energy CEM. CEM was performed on 76 patients. Focal lesions were found in 131 patients, of which 115 were histopathologically verified. The number of lesions detected in patients with multiple lesions were 40 from 48 with ABUS, 13 with FFDM and 21 with CEM. Compliance in determining the number of foci was 82% for FFDM and 91% for both CEM and ABUS. In breast types C and D, 72% of all lesions were found with ABUS, 56% with CEM and 29% with FFDM (p = 0.008, p = 0.000); all invasive cancers were diagnosed with ABUS, 83% with CEM and 59% with FFDM (p = 0.000, p = 0.023); 100% DCIS were diagnosed with ABUS, 93% with CEM and 59% with FFDM. The size of lesions from histopathology in breast ACR categories A and B was 14-26 mm, while in breast categories C and D was 11-37 mm. In breast categories C and D, sensitivity of ABUS, FFDM and CEM was, respectively, 78.05, 85.37, 92.68; specificity: 40, 13.33, 8.33; PPV (positive predictive value): 78.05, 72.92, 77.55; NPV (negative predictive value): 40, 25, 25, accuracy: 67.86, 66.07, 73.58. In breast categories A and B, sensitivity of ABUS, FFDM and CEM was, respectively, 81.25, 93.75, 93.48; specificity: 18.18, 18.18, 16.67; PPV: 81.25, 83.33, 89.58; NPV: 18.18, 40, 25; accuracy: 69.49, 79.66, 84.62. The sensitivity of the combination of FFDM and ABUS was 100 for all types of breast categories; the accuracy was 75 in breast types C and D and 81.36 in breast types A and B. The study confirms the predominance of C and D breast anatomy types and the low diagnostic performance of FFDM within that group and indicates ABUS and CEM as potential additive methods in breast cancer diagnostics.

2.
Med Sci Monit ; 29: e941072, 2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37689969

RESUMO

BACKGROUND This retrospective study from a single center aimed to compare the performance of full-field digital mammography (FFDM) vs automated breast ultrasound (ABUS) in the identification and characterization of suspicious breast lesions in 117 patients who underwent core-needle biopsy (CNB) of the breast. MATERIAL AND METHODS The study involved a group of 301 women. Every patient underwent FFDM followed by ABUS, which were assessed in concordance with BI-RADS (Breast Imaging Reporting and Data System) classification. RESULTS No focal lesions were found in 168 patients. In 133 patients, 117 histopathologically verified focal lesions were found. Among them, 78% appeared to be malignant and 22% benign. ABUS detected 246 focal lesions, including 115 classified as BI-RADS 4 or 5 and submitted to verification, while FFDM revealed 122 lesions, including 75 submitted to verification. The analysis revealed that combined application of both methods caused sensitivity to increase to 100, and improved accuracy improvement. Margin assessments in these examinations are consistent (P<0.00), the lesion's margin type with both methods depends on its malignant or benign character (P<0.03), lesion margins distribution on ABUS depends on estrogen receptor presence (P=0.033), and there was significant correlation between malignant character of the lesion and retraction phenomenon sign (P=0.033). ABUS obtained higher compliance between the size of the lesion in histopathology compared to FFDM (P>0.05). CONCLUSIONS The results shows that ABUS is comparable to FFDM, and even outperforms it in a few of the analyzed categories, suggesting that the combination of these 2 methods may have an important role in breast cancer detection.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Biópsia com Agulha de Grande Calibre , Estudos Retrospectivos , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem
3.
Diagnostics (Basel) ; 13(4)2023 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-36832275

RESUMO

Ductal carcinoma in situ (DCIS) is a non-invasive form of breast cancer that is generally indolent, however, could advance to invasive carcinoma in more than one-third of cases if left untreated. Thus, there is continuous research to find DCIS characteristics that would enable clinicians to decide if it could be left without intensive treatment. Neoductgenesis (i.e., formation of the new duct of improper morphology) is a promising, but still not sufficiently evaluated indicator of future tumor invasiveness. We gathered data from 96 cases of DCIS (histopathological, clinical, and radiological) to assess the relationship between the neoductgenesis and well-established features of high-risk tumor behavior. Furthermore, our intention was to determine which degree of neoductgenesis should be considered clinically significant. Our major finding was that neoductgenesis is strictly related to other characteristics that indicate the invasive potential of the tumor and, to achieve more accurate prediction, neoductgenesis should be accordingly recognized to less strict criteria. Therefore, we conclude that neoductgenesis is another important revelator of tumor malignancy and that it requires further investigation during prospective controlled trials.

4.
Biomedicines ; 10(10)2022 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-36289645

RESUMO

With breast cancer ranking first among the most common malignant neoplasms in the world, new techniques of early detection are in even more demand than before. Our awareness of tumors' biology is expanding and may be used to treat patients more efficiently. A link between radiology and pathology was searched for in our study, as well as the answer to the question of whether a tumor type can be seen on contrast-enhanced mammography and if such knowledge may serve as part of precision medicine.

5.
Sci Transl Med ; 14(664): eabo4802, 2022 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-36170446

RESUMO

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has a high sensitivity in detecting breast cancer but often leads to unnecessary biopsies and patient workup. We used a deep learning (DL) system to improve the overall accuracy of breast cancer diagnosis and personalize management of patients undergoing DCE-MRI. On the internal test set (n = 3936 exams), our system achieved an area under the receiver operating characteristic curve (AUROC) of 0.92 (95% CI: 0.92 to 0.93). In a retrospective reader study, there was no statistically significant difference (P = 0.19) between five board-certified breast radiologists and the DL system (mean ΔAUROC, +0.04 in favor of the DL system). Radiologists' performance improved when their predictions were averaged with DL's predictions [mean ΔAUPRC (area under the precision-recall curve), +0.07]. We demonstrated the generalizability of the DL system using multiple datasets from Poland and the United States. An additional reader study on a Polish dataset showed that the DL system was as robust to distribution shift as radiologists. In subgroup analysis, we observed consistent results across different cancer subtypes and patient demographics. Using decision curve analysis, we showed that the DL system can reduce unnecessary biopsies in the range of clinically relevant risk thresholds. This would lead to avoiding biopsies yielding benign results in up to 20% of all patients with BI-RADS category 4 lesions. Last, we performed an error analysis, investigating situations where DL predictions were mostly incorrect. This exploratory work creates a foundation for deployment and prospective analysis of DL-based models for breast MRI.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Curva ROC , Estudos Retrospectivos
6.
J Ultrason ; 22(89): 76-85, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35811591

RESUMO

Breast cancer, which is the most common cancer in women, is a major problem both in Poland and worldwide. Mammography remains the primary screening method. However, the sensitivity of mammographic screening is lower in women with dense glandular breasts due to tissue overlap and the effect of the glandular tissue obscuring the tumor and the fact that tumors and glandular tissue show similar X-ray absorption. Consequently, other methods are being sought to increase breast cancer detection rates. Currently, the most common and used methods are ultrasonography, magnetic resonance imaging and advanced mammographic methods (digital breast tomosynthesis and contrast-enhanced spectral mammography). Despite many advantages and superiority over mammography in dense breasts, they also have many disadvantages. Ultrasound is operator-dependent and the other techniques are expensive or not widely available. The Automated Breast Ultrasound Service (ABUS) technique appears to be a good option in terms of both effectiveness and lower cost.

7.
Ginekol Pol ; 93(1): 63-69, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35072254

RESUMO

Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) are the "gold standard" among gynecological imaging methods. They are important diagnostic tools used to determine the site of origin of a pelvic mass and to characterize the adnexal lesions. This paper summarizes the diagnostic performance of ultrasound, computed tomography, and magnetic resonance imaging in various gynecological diseases and tumours diagnostics.


Assuntos
Doenças dos Genitais Femininos , Ginecologia , Feminino , Humanos , Tomografia Computadorizada por Raios X , Ultrassonografia/métodos , Imageamento por Ressonância Magnética/métodos , Doenças dos Genitais Femininos/diagnóstico por imagem
8.
Med Sci Monit ; 27: e934941, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34871292

RESUMO

BACKGROUND This retrospective study included 103 patients diagnosed with rectal adenocarcinoma at a single center in Poland who underwent preoperative diffusion-weighted magnetic resonance imaging (DWI) and aimed to determine whether the apparent diffusion coefficient (ADC) was an imaging marker for tumor invasion and regional lymph node involvement. MATERIAL AND METHODS We analyzed primary staging magnetic resonance examinations of the rectum of 103 consecutive patients with histologically proven non-mucinous adenocarcinoma who underwent surgical treatment. In 85 patients, surgery was preceded by long-course chemoradiotherapy (n=18) or short-course radiotherapy (n=67). The following DWI parameters were measured: ADC mean, minimum, maximum, and standard deviation in the region of interest (ADC SD-in-ROI). Values were compared between subgroups based on histological parameters from the report: tumor stage, lymph node stage, differentiation grade, the presence of extranodal tumor deposits, angioinvasion, and perineural invasion. Statistical analysis was performed using the Mann-Whitney U test and the unilateral t test. RESULTS ADC mean values were lower for cases in which postoperative histopathological examination lymph node invasion (P=0.04) and tumor deposits were found (P=0.04). Minimal ADC value was higher in cases in which tumor deposits were not found (P=0.009). ADC SD-in-ROI values were lower in cases in which lymph nodes invasion was confirmed (P=0.014). There were no statistically significant differences for other parameters. CONCLUSIONS The ADC values in pre-treatment DWI in patients with rectal adenocarcinoma were correlated with tumor invasion and regional lymph node metastases. Therefore, ADC values from the pre-treatment MRI may help plan adjuvant therapy in patients with rectal adenocarcinoma.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Metástase Linfática/diagnóstico por imagem , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Reto/diagnóstico por imagem , Reto/patologia , Estudos Retrospectivos
9.
Breast J ; 27(10): 781-786, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34263505

RESUMO

A case report of bilateral primary angiosarcoma treated with neoadjuvant chemotherapy was presented. A routine diagnostic mammography and ultrasound examinations indicated abnormalities in both breasts of the patient, confirmed on MRI as large bilateral masses. Core needle biopsy revealed angiosarcoma G1. The treatment agreed during the interdisciplinary meeting involved chemotherapy combined with simultaneous blockade of beta-adrenergic receptors, followed by bilateral simple mastectomy. This case highlights the importance of a patient-focused care.


Assuntos
Neoplasias da Mama , Hemangiossarcoma , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Feminino , Hemangiossarcoma/diagnóstico por imagem , Hemangiossarcoma/tratamento farmacológico , Hemangiossarcoma/cirurgia , Humanos , Mastectomia , Terapia Neoadjuvante , Propranolol/uso terapêutico
10.
Diagnostics (Basel) ; 11(4)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923667

RESUMO

OBJECTIVE: The assessment of the usefulness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) when qualifying patients with uterine fibroids (UFs) for magnetic resonance-guided high-intensity ultrasound (MR-HIFU). MATERIAL AND METHODS: This retrospective, single center study included 283 women who underwent DCE-MRI and were treated with MR-HIFU. The patients were divided according to non-perfused volume (NPV) as well as by the type of curve for patients with a washout curve in the DCE-MRI study and patients without a washout curve. The studied women were assessed in three groups according to the type of uterotonics administered. Group A (57 patients) received one dose of misoprostol/diclofenac transvaginally and group B (71 patients) received oxytocin intravenously prior to the MR-HIFU procedure. The remaining 155 women (group C) were treated with the traditional non-drug enhanced MR-HIFU procedure. RESULTS: The average NPV value was higher in no washout group, and depended on the uterotonics used. CONCLUSIONS: We demonstrated a correlation between dynamic contrast enhancement curve types and the therapeutic efficacy of MR-HIFU. Our results suggest that DCE-MRI has the potential to assess treatment outcomes among patients with UFs, and patients with UFs that present with a washout curve may benefit from the use of uterotonic drugs. More studies are required to draw final conclusions.

11.
Pol J Radiol ; 86: e159-e164, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33828627

RESUMO

PURPOSE: Breast cancer is the most common cause of death from neoplastic disease in women. Among all breast anatomy types, glandular type is the most problematic concerning evaluation. While digital mammography still remains the basic diagnostic tool, one must be aware of its limitations in dense breasts. Although magnetic resonance imaging (MRI) has greatly improved sensitivity, its specificity is low. Moreover, there are contraindications for MRI for some patients, so a substitute has been searched for. This study was performed to check if contrast-enhanced spectral mammography (CESM) can be a viable option for patients with dense breasts. MATERIAL AND METHODS: The study involved 121 patients with abnormalities detected on base-line diagnostic imaging (ultrasound or mammography). The patients had subsequent examinations, both CESM and MRI performed within a maximum 2-month time interval. The sensitivity and specificity of both methods in the whole group as well as in specific breast structure types were measured and compared. RESULTS: Contrast enhancement was visible in all 121 cases on MRI, while on CESM lack of enhancement was noted in 13 cases. All of those 13 lesions turned out to be benign. There were 40 (33%) benign and 81 (69%) malignant tumours. The analysed group included 53 (44%) glandular type breast patients, 39 (32%) mixed type, and 29 (23%) fatty type. Although MRI proved to be slightly more effective in dense breasts, both methods showed similar results in the whole study group. CONCLUSION: CESM can be used with confidence in patients with glandular breast type when MRI is not available or there are reported contraindications to MRI.

12.
Ginekol Pol ; 92(2): 92-97, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33448005

RESUMO

OBJECTIVES: With the growing number of new breast cancer cases in women, new methods of imaging arise. Contrast enhanced spectral mammography (CESM) and magnetic resonance imaging (MRI) are comparable methods regarding sensitivity. The aim of this study is to check if analysis of background parenchymal enhancement on CESM can improve its usefulness. MATERIAL AND METHODS: A total of 64 patients with breast lesions found previously on ultrasound or mammography underwent MRI and CESM within less than one month. On MRI the contrast enhancement kinetics and visual BPE were evaluated. On CESM the enhancement of lesions was noted as well as a quantitative level of BPH. The gathered data was analysed in terms of patterns and relations. RESULTS: A total of 66 lesions were identified both on MRI and CESM, including 11 (17%) benign and 55 (83%) malignant lesions. Among malignant lesions 13 (20%) were assessed as intraductal and 42 (64%) as infiltrating carcinomas. The study showed correlation between the level of enhancement on CESM and the type of kinetic curve on MRI and lesion enhance-ment on CESM as well as confirmed the fact that the BPE is a destimulant in both methods of imaging. CONCLUSIONS: Evaluation of BPE level on CESM can help reading radiologists to define a lesion as malignant with higher probability than based only on the qualitative lesion enhancement level.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Carcinoma/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Diagnóstico por Imagem , Feminino , Humanos , Aumento da Imagem , Valor Preditivo dos Testes , Sensibilidade e Especificidade
13.
Anticancer Res ; 40(5): 2925-2932, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32366444

RESUMO

BACKGROUND/AIM: Contrast enhanced spectral mammography (CESM) is a novel method of breast cancer diagnosis. Benign lesions are enhanced after contrast injection on both CESM and breast magnetic resonance imaging (MRI). Kinetic curves on breast MRI facilitate differentiation between benign and malignant lesions, while on CESM there is no such possibility and we need to asses lesions based only on their level of enhancement and its patterns. The aim of this study was to compare two subjective assessments of enhancement level on CESM with numerical values measured using the region of interests (ROIs) and to categorize obtained enhancement level values. PATIENTS AND METHODS: Patients with suspicious findings on previously performed examinations were qualified for CESM. The qualitative assessment was based on the subjective classification of visible contrast enhancement as weak, medium or strong. The quantitative assessment was obtained by measurements of an average enhancement value and sigma value within the ellipsoidal shape ROI, inserted into the evaluated contrast enhancing lesion. RESULTS: The study group included 151 patients with total of 195 lesions diagnosed. It was verified how the classification based on the threshold values of %RS (percentage signal difference between enhancing lesion and background) and SDNR (signal-difference-to-noise Ratio) corresponds to a subjective assessment. CONCLUSION: Quantitative assessment of contrast enhancement on CESM is helpful in making decisions whether a lesion requires a biopsy. This can reduce the number of unnecessary biopsy procedures and reduce the cost of diagnostics.


Assuntos
Mamografia/métodos , Meios de Contraste , Feminino , Humanos
14.
Med Sci Monit ; 26: e920742, 2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32173716

RESUMO

BACKGROUND Due to the decreased sensitivity of mammography in glandular breasts, new diagnostic modalities, like contrast-enhanced spectral mammography (CESM) and digital breast tomosynthesis (DBT) have been developed. The aim of this study was to compare qualitative enhancement levels on CESM with type of kinetic enhancement curves on MRI examination. MATERIAL AND METHODS Patients qualified for the CESM examination presented some diagnostic doubts - suspected multifocality, multicentricity, or having dense glandular breast tissue. The enhancement level on CESM was described as weak, medium, or strong. Enhancement on achieved MR images was assessed on the basis of enhancement kinetic curves. The level of enhancement on CESM was associated with enhancement curves type on MRI. All lesions detected on CESM and MRI were histopathologically verified. RESULTS The study involved 107 lesions diagnosed in 94 patients: 71 lesions (66%) appeared to be infiltrating on histopathological examination, 9 lesions (8%) were non-infiltrating cancers, and 27 lesions (25%) were benign. Data analysis revealed that lesions with wash-out curve on MRI most often presented strong enhancement on CESM, while in lesions with progressive enhancement curve, strong enhancement on CESM was the rarest. The relationship between enhancement level on CESM and curve type on contrast-enhanced MRI depends on the nature of the lesion. The type of MRI curve was found to be associated with enhancement level on CESM. CONCLUSIONS We compared subjective assessments of contrast enhancement on CESM with enhancement kinetic curves on MRI. The results showed that the level of enhancement on CESM and type of kinetic curves on MRI depends on the lesion type.


Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Aumento da Imagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Biópsia com Agulha de Grande Calibre , Mama/patologia , Neoplasias da Mama/patologia , Meios de Contraste/administração & dosagem , Feminino , Humanos , Curva ROC
15.
Pathol Oncol Res ; 26(2): 1049-1056, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30989489

RESUMO

The aim of the study was to evaluate prognosis for biochemical recurrence (BR) by analysing the pathological and biological characteristics of prostate cancer (PCa) after radical prostatectomy (RP). There were 130 men with clinically localized PCa in whom pretreatment serum PSA level and Ki-67, prostate specific membrane antigen (PSMA), glucose transporter-1 (GLUT-1), vascular endothelial growth factor (VEGF), microvessel density (MVD) and human telomerase reverse transcriptase (hTERT) proteins expression, based on number of immunohistochemically positive cells (labelling index), were retrospectively studied. In order to assess the prognostic significance of analysed variables in univariate and multivariate Cox analysis, patients were dichotomized based on cut-off points chosen by receiver operating characteristic (ROC) curves. There were 83 males (63.8%) at pT stage 1-2 and 47 (36.1%) at pT stage 3-4, respectively, with median (range) age of 62.8 years (49-77), and median follow-up of 78.5 months (12-148). In 42 (32.3%) men BR was found. In univariate analysis, tumour biological features: PSA ≤ 8 ng/mL (p = 0.006), Ki-67LI ≤ 12.7% (p = 0.015), VEGFLI>11.0% (p = 0.030), and hTERTLI>6.7% (p = 0.016), but not clinicopathological parameters, appeared to be positive prognosticators for BRFS. In the Cox analysis, Ki-67 lost its significance, and clinicopathological parameters appeared to be nonsignificant. The independent negative prognostic factors for BRFS were: PSA > 8.0 ng/mL, (Hazard ratio = 2.75, p = 0.003), GLUT-1 > 19.1% (HR = 2.1, p = 0.032), VEGF≤11.0% (HR = 1, p = 0.024) and hTERT≤6.7% (HR = 1, p = 0.017). High PSA level, and GLUT-1 expression and lower VEGF and nuclear hTERT expression may indicate the great role of hypoxia in BR induction in PCa.


Assuntos
Biomarcadores Tumorais/análise , Recidiva Local de Neoplasia/metabolismo , Neoplasias da Próstata/patologia , Idoso , Intervalo Livre de Doença , Transportador de Glucose Tipo 1/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Antígeno Prostático Específico/sangue , Prostatectomia , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/mortalidade , Telomerase/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo
16.
Eur Radiol ; 29(11): 6220-6226, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31089850

RESUMO

OBJECTIVES: Contrast-enhanced spectral mammography (CESM) is a novel method for breast cancer detection. The aim of this study is to check if there is a possibility of quantitative assessment of contrast enhancement in CESM and if there is any correlation between quantitative assessment of contrast enhancement in CESM and histopathology. METHODS: A total of 167 female patients underwent CESM. All subjects previously had suspicious lesions found on mammography, breast ultrasound, or both. After imaging, the following parameters were evaluated: number of enhancing lesions in each breast and size and degree of enhancement of each lesion. Based on the collected data, the percentage signal difference between enhancing lesion and background (%RS) and signal-difference-to-noise ratio (SDNR) were measured for each lesion. RESULTS: The number of lesions detected in the study population was 195. Among all diagnosed lesions, 120 (62%) were assessed to be infiltrating cancers, 16 (8%) non-infiltrating cancers, and 59 (30%) were benign. Thirteen (7%) lesions did not enhance in CESM; all non-enhancing lesions were confirmed to be benign under histopathological examination. Analysis of enhancement indices showed that signal values within lesions and signal values within background ROIs (regions of interest) were similar in CC (craniocaudal) and MLO (mediolateral) projections. Mean %RS values were correlated with the type of enhancing lesion, infiltrating cancers having the highest values, benign lesions the lowest. CONCLUSIONS: This work has demonstrated a significant correlation between the degree of lesion enhancement in CESM and malignancy. Quantitative analysis of enhancement levels in CESM can distinguish between invasive cancers and benign or in situ lesions. KEY POINTS: • There is a possibility of quantitative assessment of contrast enhancement in CESM. • Correlation between quantitative assessment of contrast enhancement in CESM and histopathology was observed.


Assuntos
Neoplasias da Mama , Mamografia/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Meios de Contraste/administração & dosagem , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
17.
Anticancer Res ; 38(2): 1085-1095, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29374745

RESUMO

BACKGROUND/AIM: It is possible that the degree of enhancement on contrast-enhanced spectral mammography (CESM), a new diagnostic method, might provide prognostic information for breast cancer patients. Therefore, in a group of 82 breast cancer patients, we analyzed the prognostic significance of degree and pattern of enhancement on CESM as well as its relation to: (a) breast cancer immunophenotype (based on ER/PR/HER2 status) (b) podoplanin expression in cancer stroma (lymphatic vessel density plus podoplanin-positivity of cancer-associated fibroblasts), and (c) other histological parameters. MATERIALS AND METHODS: For each tumor the intensity of enhancement on CESM was qualitatively assessed as strong or weak/medium, while the pattern - as homogenous and heterogenous. RESULTS: Herein we report, for the first time, that strong and heterogenous enhancement on CESM was related to unfavorable disease-free survival of breast cancer patients (p=0.005). Moreover, the strong enhancement was more frequent in large and node-positive tumors (pT>1, pN>0) (p=0.002), as well as in carcinomas with podoplanin-sparse stroma (p=0.008). CONCLUSION: Intensity and pattern of enhancement on CESM might provide (together with the results of other diagnostic imaging methods) not only the confirmation of presence or absence of tumor, but also prognostic information.


Assuntos
Biomarcadores Tumorais/metabolismo , Neoplasias da Mama/patologia , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Glicoproteínas de Membrana/metabolismo , Células Estromais/metabolismo , Adenocarcinoma Mucinoso/metabolismo , Adenocarcinoma Mucinoso/patologia , Adenocarcinoma Mucinoso/terapia , Neoplasias da Mama/metabolismo , Neoplasias da Mama/terapia , Fibroblastos Associados a Câncer , Carcinoma Ductal de Mama/metabolismo , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/metabolismo , Carcinoma Lobular/patologia , Carcinoma Lobular/terapia , Carcinoma Papilar/metabolismo , Carcinoma Papilar/patologia , Carcinoma Papilar/terapia , Terapia Combinada , Feminino , Seguimentos , Humanos , Mamografia , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Células Estromais/patologia , Taxa de Sobrevida
18.
Strahlenther Onkol ; 193(2): 141-149, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27785518

RESUMO

INTRODUCTION: The most effective therapy in patients with limited-stage small cell lung cancer (LS SCLC) seems to be chemotherapy (using platinum-based regimens) and thoracic radiotherapy (TRT), which is followed by prophylactic cranial irradiation. MATERIALS AND METHODS: The analysed group comprised 217 patients who received combined treatment for LS SCLC, i.e. chemotherapy (according to cisplatin and etoposide schedule) and TRT (concurrent in 101 and sequential in 116 patients). The influence of chemoradiotherapy (ChT-RT) schedule on treatment results (frequency of complete response, survival rates, and incidence of treatment failure and complications) was evaluated, and the frequency and severity of pulmonary complications were analysed to identify risk factors. RESULTS: The 5­year survival rates in concurrent vs. sequential ChT-RT schedules were 27.3 vs. 11.7% (overall) and 28 vs. 14.3% (disease-free). The frequencies of adverse events in relation to concurrent vs. sequential therapy were 85.1 vs. 9.5% (haematological complications) and 58.4 vs. 38.8% (pulmonary fibrosis), respectively. It was found that concurrent ChT-RT (hazard ratio, HR 2.75), a total dose equal to or more than 54 Gy (HR 2.55), the presence of haematological complications (HR 1.89) and a lung volume receiving a dose equal to or greater than 20 Gy exceeding 31% (HR 1.06) were the risk factors for pulmonary complications. CONCLUSION: Pulmonary complications after ChT-RT developed in 82% of patients treated for LS SCLC. In comparison to the sequential approach, concurrent ChT-RT had a positive effect on treatment outcome. However, this is a factor that can impair treatment tolerance, which manifests in the appearance of side effects.


Assuntos
Quimiorradioterapia/mortalidade , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/radioterapia , Pneumonite por Radiação/mortalidade , Carcinoma de Pequenas Células do Pulmão/mortalidade , Carcinoma de Pequenas Células do Pulmão/radioterapia , Adulto , Idoso , Quimiorradioterapia/estatística & dados numéricos , Comorbidade , Relação Dose-Resposta à Radiação , Feminino , Humanos , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Polônia/epidemiologia , Prevalência , Pneumonite por Radiação/prevenção & controle , Dosagem Radioterapêutica , Estudos Retrospectivos , Fatores de Risco , Carcinoma de Pequenas Células do Pulmão/patologia , Taxa de Sobrevida , Resultado do Tratamento
19.
Eur Radiol ; 27(7): 2737-2743, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27807699

RESUMO

EUSOBI and 30 national breast radiology bodies support mammography for population-based screening, demonstrated to reduce breast cancer (BC) mortality and treatment impact. According to the International Agency for Research on Cancer, the reduction in mortality is 40 % for women aged 50-69 years taking up the invitation while the probability of false-positive needle biopsy is <1 % per round and overdiagnosis is only 1-10 % for a 20-year screening. Mortality reduction was also observed for the age groups 40-49 years and 70-74 years, although with "limited evidence". Thus, we firstly recommend biennial screening mammography for average-risk women aged 50-69 years; extension up to 73 or 75 years, biennially, is a second priority, from 40-45 to 49 years, annually, a third priority. Screening with thermography or other optical tools as alternatives to mammography is discouraged. Preference should be given to population screening programmes on a territorial basis, with double reading. Adoption of digital mammography (not film-screen or phosphor-plate computer radiography) is a priority, which also improves sensitivity in dense breasts. Radiologists qualified as screening readers should be involved in programmes. Digital breast tomosynthesis is also set to become "routine mammography" in the screening setting in the next future. Dedicated pathways for high-risk women offering breast MRI according to national or international guidelines and recommendations are encouraged. KEY POINTS: • EUSOBI and 30 national breast radiology bodies support screening mammography. • A first priority is double-reading biennial mammography for women aged 50-69 years. • Extension to 73-75 and from 40-45 to 49 years is also encouraged. • Digital mammography (not film-screen or computer radiography) should be used. • DBT is set to become "routine mammography" in the screening setting in the next future.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/organização & administração , Adulto , Idoso , Neoplasias da Mama/prevenção & controle , Europa (Continente) , Feminino , Humanos , Pessoa de Meia-Idade , Oriente Médio
20.
Med Sci Monit ; 22: 3886-3893, 2016 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-27768681

RESUMO

BACKGROUND Contrast enhanced spectral mammography (CESM) is a new method of breast cancer diagnosis in which an iodinated contrast agent is injected and dual-energy mammography is obtained in multiple views of the breasts. The aim of this study was to compare the degree of enhancement on CESM with lesion characteristics on mammography (MG) and lesion histology in women with suspicious breast lesions. MATERIAL AND METHODS The degree of enhancement on CESM (absent, weak, medium, or strong) was compared to lesion characteristics on MG (mass, mass with microcalcifications, or microcalcifications alone) and histology (infiltrating carcinoma, intraductal carcinoma, or benign) to compare sensitivity of the two modalities and to establish correlations that might improve diagnostic accuracy. RESULTS Among 225 lesions identified with CESM and MG, histological evaluation revealed 143 carcinomas (127 infiltrating, 16 intraductal) and 82 benign lesions. This is the largest cohort investigated with CESM to date. The sensitivity of CESM was higher than that of MG (100% and 90%, respectively, p=0.010). Medium or strong enhancement on CESM and the presence of a mass on MG was the most likely indictor of malignancy (55.1% p=0.002). Among benign lesions, 60% presented as enhancement on CESM (were false-positive), and most frequently as medium or weak enhancement, together with a mass on MG (53%, p=0.047). Unfortunately, the study did not find combinations of MG findings and CESM enhancement patterns that would be helpful in defining false-positive lesions. We observed systematic overestimation of maximum lesion diameter on CESM compared to histology (mean difference: 2.29 mm). CONCLUSIONS Strong or medium enhancement on CESM and mass or mass with microcalcifications on MG were strong indicators of malignant transformation. However, we found no combination of MG and CESM characteristics helpful in defining false-positive lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Mamografia/métodos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...